Liquid Cooling

Liquid Cooling Components for AI Data Centers

Source qualified liquid cooling components for direct-to-chip, immersion, and high-density data center cooling infrastructure. From QDC couplings to CDU assemblies.

Components for High-Density Liquid Cooling Infrastructure

As AI and HPC workloads push rack power densities beyond 30–100 kW, liquid cooling has become a primary thermal management strategy. We source qualified components across the full liquid cooling loop — from quick disconnect couplings and manifolds to cold plates, CDU components, pumps, valves, and sensors.

01

Quick Disconnect Couplings

Dry-break and wet-break quick disconnect couplings for server-level and rack-level liquid cooling connections. Designed for repeated connect/disconnect cycles without fluid loss.

QDCQuick DisconnectDry-breakWet-break

Key Specifications

Connection TypePush-to-connect, threaded, bayonet
Fluid CompatibilityWater, glycol/water, dielectric fluids
Pressure RatingUp to 10 bar (145 psi) typical
Temperature Range-20°C to +120°C
Body MaterialsStainless steel, brass, PVDF, PP
Seal MaterialsEPDM, NBR, PTFE, FKM
SizesDN6 to DN25 common; custom available
LeakageDry-break: zero-spill disconnect

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Direct-to-chip cooling
  • Rack manifold connections
  • CDU loop connections
  • Hot-swap server maintenance

Have a specific requirement for Quick Disconnect Couplings? Submit your specification or BOM for a sourcing review.

Request Quote
02

Liquid Cooling Manifolds

Rack-level and row-level distribution manifolds for liquid cooling loops. Custom port configurations, flow balancing, and integration with CDU supply and return circuits.

ManifoldDistributionRack CoolingCDU

Key Specifications

ConfigurationSupply + return, single-piece or modular
Port Count4 to 24 ports; custom available
Port SizesG1/4" to G1" and NPT equivalents
MaterialsStainless steel 316L, aluminum, copper
Pressure RatingUp to 16 bar
Flow BalancingFixed orifice or adjustable valve options
MountingRack rail, DIN rail, panel mount
Custom OptionsPort layout, length, end connections

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Rack-level coolant distribution
  • Row-level supply/return headers
  • Multi-server cooling loops
  • CDU integration

Have a specific requirement for Liquid Cooling Manifolds? Submit your specification or BOM for a sourcing review.

Request Quote
03

Liquid Cooling Hose Assemblies

Pre-fabricated and custom hose assemblies for data center liquid cooling loops. Flexible and semi-rigid options with compatible end fittings for rack and server connections.

HoseFlexible TubingLiquid LoopAssembly

Key Specifications

Hose TypesEPDM, PTFE-lined, silicone, PVC reinforced
Inner Diameter6 mm to 50 mm
Pressure RatingUp to 10 bar working pressure
Temperature Range-40°C to +150°C (material dependent)
End FittingsBarb, compression, push-fit, threaded, QDC
LengthsCustom cut-to-length; standard coils available
Fluid CompatibilityWater, glycol/water, dielectric fluids
CertificationOptions available per project requirement

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Server-to-manifold connections
  • CDU supply/return lines
  • Rack-to-row connections
  • Flexible loop segments

Have a specific requirement for Liquid Cooling Hose Assemblies? Submit your specification or BOM for a sourcing review.

Request Quote
04

Cold Plates

Direct-to-chip cold plates for GPU, CPU, and high-power semiconductor cooling. Custom fin geometry, port configuration, and thermal interface options for AI accelerator platforms.

Cold PlateDirect-to-ChipGPU CoolingThermal Management

Key Specifications

Base MaterialsCopper, aluminum, stainless steel
Internal StructureMicro-channel, pin-fin, serpentine
Thermal ResistanceApplication-specific; specify heat load
Pressure DropOptimized per flow rate requirement
Port ConfigurationG1/4", barb, push-fit; custom
Surface FinishLapped, anodized, nickel-plated options
MountingScrew-down, spring-loaded, custom bracket
Custom OptionsFootprint, port location, TIM integration

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • GPU direct-to-chip cooling
  • CPU liquid cooling
  • Power electronics cooling
  • AI accelerator thermal management

Have a specific requirement for Cold Plates? Submit your specification or BOM for a sourcing review.

Request Quote
05

CDU Components

Coolant Distribution Unit components including heat exchangers, reservoirs, bypass valves, and control interfaces for rack-level and row-level CDU assemblies.

CDUHeat ExchangerCoolant DistributionData Center

Key Specifications

Heat Exchanger TypesBrazed plate, gasketed plate, shell-and-tube
Capacity Range5 kW to 100+ kW per unit
Primary CircuitFacility chilled water or cooling tower water
Secondary CircuitServer-side coolant loop
Reservoir OptionsInline, standalone, pressurized
Control InterfaceAnalog, Modbus, BACnet options
MaterialsStainless steel, copper-brazed, titanium
CertificationOptions available per project requirement

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • CDU assembly and integration
  • Facility water interface
  • Rack-level heat rejection
  • Cooling loop control

Have a specific requirement for CDU Components? Submit your specification or BOM for a sourcing review.

Request Quote
06

Liquid Cooling Pumps

Centrifugal and positive displacement pumps for data center liquid cooling loops. Single and redundant configurations for CDU and rack-level circulation.

PumpCirculationCDUFlow Control

Key Specifications

Pump TypesCentrifugal, magnetically coupled, gear
Flow Range1 to 100+ L/min
Head PressureUp to 10 bar
Motor OptionsAC, DC brushless, EC motor
Speed ControlFixed speed, PWM, 0–10V, Modbus
Fluid CompatibilityWater, glycol/water, dielectric fluids
MaterialsStainless steel, PVDF, PP wetted parts
RedundancyParallel pump configurations available

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • CDU primary circulation
  • Rack-level coolant circulation
  • Redundant pump configurations
  • Variable flow systems

Have a specific requirement for Liquid Cooling Pumps? Submit your specification or BOM for a sourcing review.

Request Quote
07

Control Valves

Motorized and manual control valves for liquid cooling loop regulation, bypass control, and flow balancing in data center cooling infrastructure.

Control ValveMotorized ValveFlow ControlBypass

Key Specifications

Valve TypesBall, butterfly, globe, needle
ActuationMotorized, pneumatic, manual
Control Signal0–10V, 4–20mA, on/off, Modbus
SizesDN10 to DN100
Pressure RatingUp to 16 bar
Body MaterialsStainless steel, brass, PVDF
Leakage ClassANSI/FCI 70-2 Class IV/V options
Fail PositionFail-open, fail-closed, fail-last

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Flow regulation
  • Bypass control
  • Temperature-based modulation
  • Isolation and shutoff

Have a specific requirement for Control Valves? Submit your specification or BOM for a sourcing review.

Request Quote
08

Flow Sensors & Flow Meters

Inline and clamp-on flow sensors and meters for liquid cooling loop monitoring. Supports BMS integration and real-time flow data for cooling system management.

Flow SensorFlow MeterMonitoringBMS

Key Specifications

Measurement TypesTurbine, ultrasonic, electromagnetic, vortex
Flow Range0.1 to 500 L/min (type dependent)
Accuracy±1% to ±3% full scale
Output Signal4–20mA, pulse, 0–10V, Modbus, IO-Link
Process ConnectionInline threaded, flanged, clamp-on
Fluid CompatibilityWater, glycol/water, dielectric fluids
Temperature Range-20°C to +120°C
Display OptionsLocal display, remote display, none

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Coolant flow monitoring
  • CDU flow measurement
  • BMS integration
  • Leak detection support

Have a specific requirement for Flow Sensors & Flow Meters? Submit your specification or BOM for a sourcing review.

Request Quote
09

Pressure Sensors

Differential and absolute pressure sensors for liquid cooling loop monitoring, filter condition indication, and system health management.

Pressure SensorDifferential PressureMonitoringLoop Health

Key Specifications

Measurement TypesGauge, absolute, differential
Pressure Range0–1 bar to 0–25 bar
Accuracy±0.1% to ±0.5% full scale
Output Signal4–20mA, 0–10V, IO-Link, Modbus
Process ConnectionG1/4", G1/2", NPT, flush diaphragm
Wetted Materials316L stainless, PVDF, ceramic
Temperature Range-20°C to +125°C
ProtectionIP65, IP67, IP68 options

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Loop pressure monitoring
  • Differential pressure measurement
  • Filter condition monitoring
  • Pump performance monitoring

Have a specific requirement for Pressure Sensors? Submit your specification or BOM for a sourcing review.

Request Quote
10

Leak Detection Sensors

Point and rope-style leak detection sensors for data center liquid cooling infrastructure. Provides early warning of coolant leaks to protect IT equipment.

Leak DetectionWater SensorData Center SafetyBMS

Key Specifications

Sensor TypesPoint sensor, rope/cable sensor, zone controller
Detection FluidWater, glycol/water, conductive fluids
Response Time< 1 second typical
Cable LengthUp to 200m per zone (rope type)
OutputRelay, 4–20mA, Modbus, BACnet
Alarm IntegrationBMS, DCIM, standalone alarm panel
InstallationFloor-mount, rack-mount, cable routing
CertificationOptions available per project requirement

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Under-floor leak detection
  • Rack-level leak detection
  • CDU leak monitoring
  • Raised floor and hot aisle containment

Have a specific requirement for Leak Detection Sensors? Submit your specification or BOM for a sourcing review.

Request Quote
11

Filters & Strainers

Y-strainers, basket filters, and inline filters for liquid cooling loop particle removal and fluid quality maintenance. Protects pumps, valves, and cold plates from contamination.

FilterStrainerParticle RemovalFluid Quality

Key Specifications

Filter TypesY-strainer, basket filter, cartridge filter
Filtration Rating25 micron to 500 micron mesh
SizesDN15 to DN100
Pressure RatingUp to 16 bar
Body MaterialsStainless steel 316L, brass, cast iron
Screen MaterialsStainless steel mesh, perforated plate
Blow-downManual, automatic options
ConnectionsThreaded, flanged, tri-clamp

Specifications are indicative. Final parameters depend on manufacturing partner and project configuration.

Typical Applications

  • Coolant loop particle filtration
  • Pump inlet protection
  • Cold plate protection
  • System commissioning flushing

Have a specific requirement for Filters & Strainers? Submit your specification or BOM for a sourcing review.

Request Quote

Source Liquid Cooling Components